Chest Meeting
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
COPYRIGHT © 2007 by the American College of Chest Physicians.
This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Reddy, A. P.
Right arrow Articles by Reddy, S. P.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Reddy, A. P.
Right arrow Articles by Reddy, S. P.

Smoking Cessation


Tuesday, October 23, 2007

2:30 PM - 4:00 PM

NONINVASIVE PULSE CO-OXIMETRY AS A TOOL TO DETECT SMOKING STATUS IN AN OUTPATIENT SETTING

Ashray P. Reddy, High School*, Mary L. Zaremba, APRN, BC and Sridhar P. Reddy, MD MPH FCCP

Detroit Country Day School, Beverly Hills, MI

PURPOSE: There are several methods available to detect smoking status. We evaluated the use of a noninvasive pulse co-oximeter that measures carboxyhemoglobin and methhemoglobin as a tool to detect smoking status in a outpatient setting.

METHODS: We measured at each outpatient visit carboxyhemoglobin and methhemoglobin using a Rad 57 pulse co-oximeter. We asked patients questions regarding their smoking status. The data was analyzed by using standard t-test and we calculated sensitivity, specificity, positive predictive value, and negative predictive value along with pre and post test probabilities.

RESULTS: Of the 476 patient visits 98 were smokers, 72 second hand smokers, and 306 non smokers. At a cutoff for carboxyhemoglobin at 6% and higher the sensitivity was 46% with a specificity of 95% to detect a smoker. The positive predictive value was 76% with a negative predictive value of 85%. For methhemoglobin at a cutoff of .7% and higher the sensitivity was 45% with a specificity of 92%. The positive predictive value was 65% with a negative predictive value of 84% for a smoker. The carboxyhemoglobin levels for smokers was 5.9+/-4.45% while the carboxyhemoglobin levels for non smokers was 1.95+/-1.55%. This difference was significant(P=3.60928E-14). The methhemoglobin levels for smokers was .66+/-.31% while the methhemoglobin levels for non smokers was .38+/-.19%. This difference was significant(P=3.34689E-14).The carboxyhemogloblin levels for second hand smokers was 2.79+/-2.89% while the carboxyhemoglobin levels for non smokers was 1.94+/-1.55%. This difference was significant(P=0.001913). The methhemoglobin levels for second hand smokers was 0.49+/-0.25% while the methhemoglobin levels for non smokers was 0.38+/-0.19%. This difference was significant(P=0.000653).

CONCLUSION: In an outpatient clinic setting pulse co-oximetry can be used as a cheap quick and noninvasive method to detect smoking status.

CLINICAL IMPLICATIONS: Detecting smoking status is key to effectively counselling patients regarding smoking cessation. Pulse co-oximetry can be effectively used in this situation. In addition its use may be extrapolated to other public health settings such as adolescent smoking cessation programs within school systems to help prevent smoking in vulnerable populations.

DISCLOSURE: Ashray Reddy, No Financial Disclosure Information; No Product/Research Disclosure Information